Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia
All New Fluke 972B Temperature Humidity Meter and Fluke 972ES External Sensor!

All New Fluke 972B Temperature Humidity Meter and Fluke 972ES External Sensor!

By Jonel Patrick Opsimar March 26, 2024

Introducing our newest lineup additions: the Fluke 972B Temperature Humidity Meter and Fluke 972ES External Sensor. The Fluke 972B simplifies the collection of precise humidity and temperature data with its intuitive interface and sleek design, ensuring comfortable handling. Plus, with the 972ES External Sensor, users can extend temperature measurements and effortlessly reach challenging locations, enhancing the meter's versatility. The Fluke 972B and Fluke 972ES are indispensable tools, as they provide crucial insights into indoor air quality (IAQ), ensuring optimal environmental conditions. HVAC service contractors, facility maintenance and engineering technicians, and R&D and manufacturing engineers rely on these instruments to maintain air quality standards, identify potential issues, and ensure the well-being of occupants. 

Features and Benefits

  • The Fluke 972B includes an internal sensor for standard indoor environments and an external sensor (Fluke 972ES) for expanded measurement capabilities in challenging locations.
  • Accuracy of ± 0.5 °C and ± 3% RH, to meet industrial grade testing requirements. 
  • 99 sets of stored data, easy to review.
  • Comfortable grip and ergonomic design.
  • Reinforced sensor protective cover for worry-free operation.
  • Data logging in 5 minute intervals.

Who will buy?

Job Title

  • Maintenance Technicians and Managers
  • HVAC Technicians
  • Plant Electricians
  • Livestock Environment Controllers

Industries

  • Manufacturing plants 
  • Cold chain logistics 
  • Storage refrigeration

Residential Indoors

  • Indoor temperature measurement
  • Relative humidity reading
  • Wet bulb measurement
  • Dew point measurement

Commercial Indoors

  • Indoor temperature measurement
  • Relative humidity reading
  • Wet bulb measurement
  • Dew point measurement

Industrial Indoors

  • Indoor temperature measurement
  • Relative humidity reading
  • Wet bulb measurement
  • Dew point measurement

Specifications: Fluke 972B/972ES Temperature Humidity Meter

  972B 972ES
Detailed Specifications
Sensor Type Internal + External External
Temperature Measurement Range Internal sensor: -30.0 °C to 65.0 °C;
External sensor: -40.0 °C to 99.9 °C
-40.0 °C to 99.9 °C
Temperature Accuracy Internal sensor: ±0.5 °C (-30.0 °C to 65.0 °C)
External sensor: ±0.5 °C (-30.0 °C to 65.0 °C);
±0.7 °C (others)
±0.5 °C (-30.0 °C to 65.0 °C);
±0.7 °C (others)
Temperature Resolution 0.1 °C
Dew Point Temperature Range -40.0 °C to 99.9 °C N/A
Resolution 0.1 °C N/A
Wet Bulb Temperature Range -20.0 °C to 60.0 °C N/A
Resolution 0.1 °C N/A
Humidity Range 0.0% RH to 99.9% RH
Accuracy ±3% RH (≥20.0% RH to ≤80.0% RH @ 25 ℃)
±5% RH (≥1% RH to <20% RH, >80% RH to ≤95% RH @ 25℃)
Unspecified for others
Resolution 0.1% RH
Data Storage Yes. Up to 99 sets N/A
Display 2-line LCD display, with backlight No
Auto-off Power off after 20 min without any operation N/A
Max/Min/Avg Yes N/A
Auto Logging Mode Yes N/A
General Specifications
Temperature Operating -30 °C to 70 °C -40 °C to 70 °C
Storage -30 °C to 70 °C, <80% RH (without battery) -40 °C to 70 °C, <80% RH
Altitude Operating 2000 m
Storage 12 000 m
Relative Humidity Operating 0% RH to 99% RH
Storage <80% RH
Power Supply Battery Type 2 x AAA Batteries
Battery Life 1000 hrs for continuous operating, backlight off
Safety IEC61010-1, Pollution Degree 2
Dimensions (L x W x H) 211 × 58 × 40 mm 264 × 33 × 28 mm
Weight 172 g (body) 127 g
Electromagnetic Environment (EMC) IEC 61326-1: Portable, Electromagnetic Environment; IEC 61326-2-2; CISPR 11: Group 1; Class A
Group 1: Equipment intentionally generates and/or uses conductive-coupled RF energy, which is necessary for its internal operation.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
IP Rating IEC 60529: IP30, non-operating

 


Older Post


0 comments


Leave a comment

Please note, comments must be approved before they are published

You might like to Read Our Buying Guides View all

Laserman’s Guide to Buying a Laser Level, Best Laser Level in Australia, construction laser level

Laserman’s Guide to Buying a Laser Level

Best laser level australia At Laserman, we understand that it can be difficult to find a laser level that covers all of your project needs. Whether...

Buying Guide - Best laser level Australia, laser level tool, construction laser level

Buying Guide - Best laser level Australia

Laser Levels  What is a Laser Level?  Types of Laser Levels Factors to Consider When Choosing a Laser Level Applications of Different Types of...

Buying Guide - Survey/GPS

Buying Guide - Survey/GPS

Surveying Instruments  What are Surveying Instruments?  Types of Surveying Instruments  What are Surveying Instruments  Surveying Instruments ar...

Buying Guide - Industrial

Buying Guide - Industrial

Industrial Laser Tools  Types of Industrial Laser Tools Applications of Different Types of Industrial Laser Tools  Types of Industrial Laser Too...